Controlled exposure. Measurable response.


Controlled VOC dosing
An integrated benchtop platform for controlled gas and VOC sensor testing—from concentration calculation and heated exposure to real-time electrical characterization and sensor recovery.
Heated glass chamber
Real-time measurement
Recovery cycling


Complete the sensing experiment
without assembling every subsystem.
One integrated platform
Schnaiffer combines the essential hardware and workflow required for repeatable sensor exposure, measurement and recovery—allowing researchers to concentrate on sensing materials, device performance and experimental data.
04 / RECOVER
Flow and Recovery
Restore the baseline and repeat exposure-recovery cyclesa
01 / CONTROL
Defined VOC dosing
Calculate and introduce the required liquid analyte quantity
02 / EXPOSE
Heated test chamber
Mount and expose the sensor under controlled temperature
03 / MEASURE
Electrical Characterization
Monitor resistance, capacitance, impedance, voltage or current
Measure the sensor inside its actual exposure environment.
The sensing device is positioned on an electrically insulating ceramic stage inside the glass chamber. Electrical connections are routed outside for continuous measurement during VOC exposure.
Sensor mounting & measurement
Measurable electrical parameters
>Resistance >Conductance >Capacitance >Impedance >Voltage >Current


Generate defined ppm or ppb test conditions.
The concentration calculator determines the liquid injection volume from the selected analyte, chamber volume, target concentration and experimental temperature. The calculated dose is introduced through a dedicated inlet using a microsyringe.
Pump outlet
Recovery or exhaust flow
Controlled VOC exposure
Multi-port glass chamber
Pump inlet
Airflow and baseline recovery


VOC inlet
Controlled microsyringe injection
Temperature feedback
Thermocouple or RTD connection
Compatible with digital multimeters, LCR meters, impedance analyzers, source-measure units and dedicated sensor-interface modules.
From a functional film to
validated sensor performance.
Combine the test platform with Schnaiffer interdigitated electrode substrates, IDE holders and sensor-interface modules.
Complete sensor-development workflow
1
Select the IDE substrate
6
Evaluate performance
2
Deposit the sensing film
3
Mount the device
4
Apply controlled exposure
5
Measure electrical response


Move beyond simple response detection.
Evaluate how the device responds, recovers, drifts and performs across concentration, temperature and repeated test cycles.
Response and recovery time
Characterize adsorption and baseline restoration.
Sensor performance characterization
Response versus concentration
Build sensitivity and calibration relationships.
Temperature dependence
Identify the effect of operating temperature.
Repeatability and cycling
Compare successive exposure–recovery cycles
Research applications
> Gas sensor research > VOC sensor development > Nanomaterial characterization > Environmental monitoring R&D > Electronic-nose development > Laboratory breath-biomarker research
Baseline stability and drift
Observe signal movement across extended testing.